Transformer Test Equipment

  • Transformer Turn Ratio Tester

    Transformer Turn Ratio Tester

    In the production process of semi-finished and finished power transformers, before the newly installed transformers are put into operation and according to the preventive test regulations, it is required to test the turn ratio or voltage ratio of the running transformers, so as to check the correctness of the turn ratio of transformers, the condition of tap changer, whether the transformers are short circuited between turns, and whether the transformers can operate in parallel.
    The traditional bridge reading is not intuitive, so the conversion can only be carried out phase by phase. RDB- II transformer ratio tester overcomes the shortcomings of traditional ratio bridge test, which is easy to operate and intuitive. TTR tester adopts three-phase precision inverter power supply, and has fast test and high accuracy.

    Email Details
  • Dual-channel DC Resistance Tester 10A

    Dual-channel DC Resistance Tester 10A

    The transformer DC resistance tester is a necessary test item for semi-finished product, finished product factory test, installation, overhaul, change of tap changer, handover test and preventive test of power department in transformer manufacturing. The Dual-channel DC Resistance Tester can check the welding quality of the winding joint and whether there is inter turn short circuit in the winding, whether the contact of each position of the voltage tap changer is good, whether the actual position of the tap changer is consistent with the indicated position, whether the outgoing line is broken, and whether there is broken strand in the parallel winding of multiple wires. In order to meet the needs of fast measurement of transformer DC resistance, our company developed RDZR-10A DC resistance tester. The Transformer DC Resistance Tester adopts new power supply technology, which has the characteristics of small volume, light weight, large output current, good repeatability, strong anti-interference ability, perfect protection function and so on.
    The whole dc resistance meter is controlled by high-speed single-chip microcomputer, with high degree of automation, automatic discharge and discharge alarm function. The DC Resistance Analyzer has the advantages of high precision and easy operation, and can realize the fast measurement of transformer direct resistance

    Email Details
  • Transformer variable ratio tester

    Transformer variable ratio tester

    In the production process of semi-finished and finished power transformers, before the newly installed transformers are put into operation, it is required to test the turn ratio or voltage ratio of the running transformers, so as to check the correctness of the turn ratio of transformers, the condition of tap changer, whether the transformers are short circuited between turns, and whether the transformers can operate in parallel. The traditional bridge reading is not intuitive, so the conversion can only be carried out phase by phase.
    RDB-II transformer turn ratio tester overcomes the shortcomings of traditional ratio bridge test, which is easy to operate and intuitive. The TTR adopts three-phase precision inverter power supply, and has fast test and high accuracy

    Email Details
  • Transformer On Load Switch Tester

    Transformer On Load Switch Tester

    The RDKC-2000 transformer on-load tap-changer is the only moving part connected to the transformer circuit. Therefore, the detection of the on-load tap-changer is becoming more and more important. In the "power equipment transfer and preventive test procedures", asked to check the on-load tap-changer action sequence, measurement switching time. The instrument is mainly used to measure the transformer on-load tap-changer transition waveform, transition time, the instantaneous transition resistance, three-phase synchronization and so on.
    The instrument is highly intelligent, menu prompts, simple operation. Instrument small size, light weight, anti-interference ability, greatly reducing the labor intensity of the site staff, is the power supply units, transformer manufacturing industry to ensure safe production, improve product quality ideal instrument.

    Email Details
  • RD6000 Anti Interference Automatic Test Instrument For Different Frequency Dielectric Loss

    RD6000 Anti Interference Automatic Test Instrument For Different Frequency Dielectric Loss

    The anti-interference pilot frequency dielectric loss tester is a high-precision instrument for testing the dielectric loss tangent and capacitance of various high-voltage power equipment in power plant, substation and other field or laboratory.
    The Capacitance Dielectric Loss & Dissipation Factor Tester is an integrated structure with built-in dielectric loss test bridge, variable frequency voltage regulating power supply, step-up transformer and SF6 high stability standard capacitor. The test high-voltage source is generated by the inverter inside the instrument, which is used to test the tested object after boosting by the transformer. The frequency can be 45Hz or 55Hz, 55Hz or 65Hz, 47.5 or 52.5Hz. The digital notch technology avoids the interference of power frequency electric field on the test, and fundamentally solves the problem of accurate measurement under the interference of strong electric field. At the same time, it is suitable for the situation of power supply detection by generator after all power failure.

    Email Details
  • Transformer TTR tester

    Transformer TTR tester

    In the production process of semi-finished and finished power transformers, before the newly installed transformers are put into operation and according to the preventive test regulations, it is required to test the turn ratio or voltage ratio of the running transformers, so as to check the correctness of the turn ratio of transformers, the condition of tap changer, whether the transformers are short circuited between turns, and whether the transformers can operate in parallel.
    The traditional bridge reading is not intuitive, so the conversion can only be carried out phase by phase. RDB-Ⅲ transformer ratio tester overcomes the shortcomings of traditional ratio bridge test, which is easy to operate and intuitive. TTR tester adopts three-phase precision inverter power supply, and has fast test and high accuracy.

    Email Details
  • RDXC-3000A Transformer Demagnetization Tester Automatic Transformer Transformer Degausser

    RDXC-3000A Transformer Demagnetization Tester Automatic Transformer Transformer Degausser

    Transformer Demagnetization Tester is a special equipment to eliminate the remanence after the DC resistance test of a large power. It is very important to protect the transformer from the impact of the inrush, the safe operation and the prolongation of the life of the transformer.
    Our Transformer Degaussing Test Kit,Adopt advanced and reasonable compound current method technology,demagnetize power transformer,the demagnetization detection is also quantified

    Email Details
  • <
  • 1
  • 2
  • 3
  • Total 25 Records
Get the latest price? We'll respond as soon as possible(within 12 hours)