digital micro ohmmeter contact loop resistance tester
- Wrindu
- RDHL-100H
The instrument panel is ergonomically designed, in line with operating practices, use high-frequency switching power supplies and digital circuit technology for measuring the contact resistance of the circuit switch control device. Test current is DC 100A. In the case of DC 100A can be directly measured contact resistance test result with a large-screen LCD display, and with data storage, print, time settings and other functions, and another gear 50A for user selection; custom test time, maximum 599S, much larger than the standard requirements of 60S; resolution 0.01μΩ and very stable. Meet the power; the electricity sector on-site high voltage switch maintenance and high-voltage switch factory contact resistance testing requirements.
Description
RDHL-100H loop resistance tester is designed for measuring loop resistance of switching control equipment using high-frequency switching power supply technology and digital circuit technology. Test current of the tester is DC 50A or 100A. The tester can measure the loop resistance at those values and display results in digital. It is high precision and good stability and can meet most power systems’ requirements in onsite high-voltage switches maintenance and high-voltage switches factory loop resistance measurement.
Features
1. High current, adopts new switching power techniques, can output current long time and continuously , overcome the malpractice of instantaneous current of the impulse type power, can effectively break through the oxide film of the switch contact, get accurate test result.
2. High stability, under strong interference, the last number displayed by the LCD within the range of ±1, with steady reading and good reproducibility.
3. High precision: adopts double channels high-speed 16bits Σ-Δ AD to sample, digital signal processing technique, the maximum resolution up to 0.01μΩ.
4. Intelligent: use high performance CPU, system can switch the measurement range according the size of the signal when testing, ensure the accuracy. The over-temperature protection circuit can auto stop output the current when the device exceeds the rated temperature to ensure the safety.
5. High quality: key components adopts imported components, uses temperature compensating circuit in perfect design which eliminates the effect to test result by temperature, meanwhile strengthen the resistance to shock by using the military connector.
6. Powerful: current could be 50A, 100A, measurement time 5s~599s, more powerful than other equipments.
7. Friendly man-machine interface: enter the data by rotating mouse, easy and convenient, can set the data, time by yourself, save and print the test result in time.
8. U-disk: Store the data to U disk by U-disk interface, combining PC software for further analysis and processing of the measurement data.
9. Easy to carry: small in volume, light in weight.
For more circuit breaker test equipment, please click the circuit breaker test equipment list
If your company has purchasing needs, please click to contact us, we are always ready to provide you with
quotes and solutions.
Specifications
1. Measurement range: 0~2999.9μΩ
2. Resolution: 0~99.99, 0.01μΩ; 100.0~2999.9, 0.1μΩ
3. Measured current: DC 50A, 100A, fixed output.
4. Accuracy : ±(0.5% rd+2d)
5. Continuous working time: 5s~599s
6. Display :LCD
7. Communication mode: U disk
8. Power supply: AC220V±10% 50Hz
9. Power of the whole machine:600W
10. Maximum storage record: 200
11. Service conditions: temperature- 10℃~40℃ humidity≤80 %RH
12. Dimension: 360×300×250 mm3
13. Weight: 8kg (the accessories not included)