RDCD-Ⅱ/535T Cable Test High-voltage Signal Generator (single gear)
- Wrindu
- Shanghai, China
- about 25 days
- 5000 set/month
The high-voltage pulse generator is mainly used to quickly detect cable faults of 35kV and below. It integrates high-voltage power supply, pulse energy storage capacitor, discharge ball gap and sampler.
Simple wiring, easy to operate, safe and reliable. It has functions such as overcurrent, overvoltage and overheating. It is with zero start protection, high voltage side measurement, real-time display of residual voltage. The meter displays the current and voltage pointer in real time which is intuitive and reliable.
Description
RDCD-Ⅱ Cable Fault Testing System is the achievement of our company's continuous improvement and innovation for many years. The product is the leading product of cable fault testing instruments at home and abroad at present, applying modern power electronic technology. It can also measure low resistance, short circuit, open circuit and broken line faults, high resistance leakage and high resistance flashover faults of various high frequency coaxial cables, local telephone cables, street lamp cables and buried wires with different cross sections by using the distance measurement, path finding and location of the main insulation fault points of power cables with voltages of 35kV and below. The system consists of four parts: RDCD-II/502 Cable Fault Pre-locator, RDCD-II/535T Cable Test High-voltage Signal Generator, RDCD-II/503D Cable Fault Locator and RDCD-II/507 Pipeline Detector. The characteristics and parameters of each part are as follows:
Features
l High voltage pulse output is uniform and controllable;
l With double 1.5-level indicator display of current and voltage, it is intuitive and clear, and the impulse discharge process is clear at a glance;
l High voltage measurement, real-time and accurate;
l With zero starting protection function, it is safe and reliable;
l With three-gear voltage range and capacitor capacity switching function;
l Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the equipment;
l Discharge time can be selected in two modes: timing mode and manual mode;
l With DC withstand voltage function;
l Install the internal high-precision test cable fault sampling waveform module;
l Humanized handcart design, easy to move;
For more cable fault test equipment, please click on the cable fault test solution list
If your company has purchasing needs, please click to contact us, we are always ready to provide you with quotes and solutions.
Specifications
l Impulse high voltage: 0 ~ 32kV, 0 ~ 16kV, 0 ~ 8kV.
l High voltage division: the voltage accuracy is 1.5.
l Built-in capacitor: 4μF/32kV, 16μF/16kV, 64μF/8kV three-stage adjustment
l Discharge power: 2048J.
l Impact time: impact automatically for about 5 seconds, and impact manually for any control time.
l Impact power: 2kVA
l Operating power supply: AC 220V±10% 50Hz±2Hz
l Environment: -20 ~+50℃