High Accuracy Insulation Resistance Tester Earth Ground Resistance Meter Megger Megohmmeter Voltmeter

  • High Accuracy Insulation Resistance Tester Earth Ground Resistance Meter Megger Megohmmeter Voltmeter
  • High Accuracy Insulation Resistance Tester Earth Ground Resistance Meter Megger Megohmmeter Voltmeter
  • High Accuracy Insulation Resistance Tester Earth Ground Resistance Meter Megger Megohmmeter Voltmeter
  • High Accuracy Insulation Resistance Tester Earth Ground Resistance Meter Megger Megohmmeter Voltmeter
  • High Accuracy Insulation Resistance Tester Earth Ground Resistance Meter Megger Megohmmeter Voltmeter
High Accuracy Insulation Resistance Tester Earth Ground Resistance Meter Megger Megohmmeter Voltmeter
  • Wrindu
  • Shanghai, China
  • about 25 days
  • 5000 set/month
  • RDIR3480A

RDER2100C+ Multi-Function Clamp Earth Resistance Tester is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment. In the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use. The tester can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the RDER series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance. The equipment can also measure the leakage current and neutral current of the grounding system.

RDIR3480A Insulation Resistance Tester 





Product features 

1.      Controllable off-white backlight, suitable for dark places.

2.      With automatic discharge function.

3.      With automatic shutdown function.

4.      With data hold function.


Product specifications and technical parameters

1.      Measurement Range & Accuracy

Measurement

Output Voltage

Range

Accuracy

Resolution

Insulation Resistance

50V(±2%)

100KΩ~5MΩ

±3%rdg±5dgt

0.01MΩ

5MΩ~100MΩ

±5%rdg±5dgt

0.1MΩ

100MΩ~1GΩ

±5%rdg±5dgt

1MΩ

1GΩ~4GΩ

±10%rdg±5dgt

10MΩ

250V(±2%)

500KΩ~25MΩ

±3%rdg±5dgt

0.01MΩ

25MΩ~500MΩ

±5%rdg±5dgt

0.1Ω

500MΩ~5GΩ

±5%rdg±5dgt

1MΩ

5GΩ~20GΩ

±10%rdg±5dgt

10MΩ

500V(±2%)

1MΩ~50MΩ

±3%rdg±5dgt

0.1MΩ

50MΩ~1GΩ

±5%rdg±5dgt

1MΩ

1GΩ~10GΩ

±5%rdg±5dgt

10MΩ

10GΩ~40GΩ

±10%rdg±5dgt

0.1GΩ

1kV (±2%)

2MΩ~100MΩ

±3%rdg±5dgt

0.1MΩ

100MΩ~2GΩ

±5%rdg±5dgt

1MΩ

2GΩ~20GΩ

±5%rdg±5dgt

10MΩ

20GΩ~80GΩ

±10%rdg±5dgt

0.1GΩ

2.5kV (±2%)

10MΩ~250MΩ

±3%rdg±5dgt

0.1MΩ

250MΩ~5GΩ

±5%rdg±5dgt

1MΩ

5GΩ~50GΩ

±5%rdg±5dgt

10MΩ

50GΩ~200GΩ

±10%rdg±10dgt

1GΩ

Voltage Measurement

AC/DC:0.0V~750V

±5%rdg±5dgt

0.1V

2.      Technical Parameters

 Function

 insulation resistance test, DAR, PI, AC/DC voltage test

 Power Supply

 DC 1.5V LR14×6pcs

 Rated Voltage

 50V / 250V / 500V / 1kV / 2.5kV

 Insulation Resistance Range

 0.1MΩ~200GΩ

 Voltage Range

 AC/DC 0V ~ 750V

 Shout Circuit Current

 2mA Max

 Max Capacitive Load

 1uF

Dielectric Absorption Ratio Test (DAR)

Yes

Polarization Index Test (PI)

Yes

 Shift

 Turn the shift rotary knob to select the appropriate gear

 Backlight

 Controllable off-white backlight, suitable for dark places

 Display Mode

 4 digital LCD display

 Measurement indication

 LED flicker and buzzer ring in measurement

 LCD Size

 108mm×65mm

 Meter Dimension

 212mm×175mm×76mm

 Test Wires

 High voltage bar test wire: Red 1pc; Probe test wire: Black 1pc; Alligator clip test wire: 1pc; Alligator clip: 1pc

 Test Time

 The single test time is 12 min. During the test, the user can stop automatically or automatically stop after 12 min, and the screen display measurement data

 Battery Voltage

 Battery voltage symbol display, when battery voltage is low will remind to replace the battery in time

 Automatic Discharge

 Automatic release the voltage of the measured object, During discharging,symbol flash.Discharge completion symbol extinguish

 Auto Shutdown

 15 minutes after boot up, the meter shuts down automatically without any operation

 Power Consumption

 Standby: about 40mA (backlight off); Start up with backlight: about 50mA; Measurement: about 100mA (backlight off)

 Weight

 1230g

 Working Temperature and Humidity

  -10℃ ~ 40℃; below 80%RH

 Storage Temperature and Humidity

  -20℃~60℃; below 70%RH

 Suitable Safety Standard

 IEC61010-1(CAT Ⅲ 300V  CAT IV 150V  Pollution 2)