RDZ5261 AC DC Dielectric Withstand Voltage Tester can intuitively, accurately and quickly test the breakdown voltage, leakage current and other electrical safety performance indicators of various measured objects. In addition to being used for safety testing, this instrument can also be used as a high-voltage source to test components and complete machine performance.

Description

RDZ5261 programmable ac dc dielectric withstand voltage tester is a programmable withstand voltage tester mainly used for electrical strength testing. The voltage rises according to the set time gradient. It has 4 sets of memory modes, with RS232 and PLC interfaces. It can intuitively, accurately and quickly test the breakdown voltage, leakage current and other electrical safety performance indicators of various measured objects. In addition to being used for safety testing, this instrument can also be used as a high-voltage source to test components and complete machine performance.


Features 

1.   This ac dc dielectric withstand voltage tester uses a microprocessor as the core, and the test channel captures the parameter changes of the electrical appliance under test during the test process in real time .

2.      The tester uses a backlit LCD display with soft light, high clarity, and little impact from ambient light.

3.      Character menu, concise and easy to understand.

4.      Display test results in full screen, with test condition memory function.


Specifications 


1.     Test output voltage:   

AC: 0 ~ 5.00 kV ( can be set)         Accuracy: ± 3% ± 3 dgt @ 0.5 ~ 5.00 kV

DC: 0 ~ 6.00 kV (can be set)           Accuracy: ± 3% ± 3 dgt @ 0.5 ~ 6.00 kV

2.     Test output current:

AC: 0 ~ 20 mA (can be set)          Accuracy: ± 3% ± 3 dgt @ 0.2 ~ 20 mA

DC: 0 ~ 10 mA (can be set)            Accuracy: ± 3% ± 3 dgt @ 0.2 ~ 10 mA

3.     Timing: 1999 s (can be set)        Accuracy: ± 3% ± 1 second

4.     Output power : AC 100VA , DC 60VA

5.     Power supply: AC220V ± 10 % , 50Hz/60Hz

6.     Safety protection functions: a. Short circuit shutdown and alarm. b. Out of tolerance alarm.

7.     Memory function: The tester can save commonly used withstand voltage modes.

8.     Interface: RS232, PLC