Insulating Oleic Acid Value Tester

  • Insulating Oleic Acid Value Tester
Insulating Oleic Acid Value Tester
  • Wrindu
  • RDSZ-303D

1.Three cup integrated design, suitable for testing the oleic acid value of transformer oil and steam turbine;
2.The insulating oleic acid value tester adopts microcomputer control to automatically complete liquid addition, stirring, titration, and endpoint determination
3.Touch type color LCD display screen, accurate parameter input response, stable and reliable display performance;
4.The insulating oleic acid value tester can display up to 35 sets of measurement results separately and print out multiple parameters related to the measurement.
5.The design structure of the case is simple and reasonable, the volume is small and exquisite, and the appearance is elegant and generous;


Description


The full-automatic oleic acid value tester is a high accuracy and full digital industrial instrument developed by our company in accordance with the relevant provisions of national standards and after long-term unremitting efforts. The detection of oleic acid value of transformer and steam turbine is a routine inspection item of power system and oil filled electrical equipment of industrial and mining enterprises, and the full-automatic oleic acid value tester is a special equipment developed by our company for the above-mentioned oil acid value measurement. The instrument is controlled by a full-automatic digital microcomputer. Based on the acid-base neutralization reaction of chemical analysis, it adopts the detection method of acid extraction and neutralization titration, which makes the accuracy and precision of measurement ideal.


Features


  • Three cup integrated design, suitable for testing the oleic acid value of transformer oil and steam turbine;

  • The instrument adopts microcomputer control to automatically complete liquid addition, stirring, titration, and endpoint determination

  • Touch type color LCD display screen, accurate parameter input response, stable and reliable display performance;

  •  It can display up to 35 sets of measurement results separately and print out multiple parameters related to the measurement.

  • The design structure of the case is simple and reasonable, the volume is small and exquisite, and the appearance is elegant and generous;


Parameters




 

Picture

 Insulation Oleic Acid Value Tester

Model

RDSZ-303D

1

Test range

0.001~ 0.400 mgKOH/g

2

Minimum resolution

0.001 mgKOH/g

3

Repeatability

2~5% (RSD)

4

Measurement accuracy

l  The acid value is ± 0.003 mgKOH/g between 0.001 and 0.100 mgKOH/g

l  The acid value between 0.100 and 0.400 mgKOH/g is 2~5% of the indicated value

5

Ambient temperature

0 ~ 40 ℃

6

Relative humidity

≤ 85%

7

Working power supply

AC220V ± 10%, 50Hz

 


Get the latest price? We'll respond as soon as possible(within 12 hours)